Heat Sink Temperature Calculator
Tj = Ta + P Σθ. 10 W at 25 °C with 1.5+0.5+3 °C/W is 75 °C.
Calculator
Formula
Junction temperature
Tj = Ta + P (θJC + θCS + θSA) Power budget
Pmax = (Tjmax − Ta) / Σθ Required heat-sink
θSA_req = (Tjmax − Ta)/P − θJC − θCS Variables
| Symbol | Meaning | Unit | Typical range | Precision | Default |
|---|---|---|---|---|---|
| mode | Mode | — | — | 1 sig | forward |
| P | Dissipation | W | ≥ 0 µW | 4 sig | 10 W |
| Ta | Ambient | °C | — | 4 sig | 25 °C |
| θJC | Junction-to-case | °C/W | ≥ 0 °C/W | 4 sig | 1.5 °C/W |
| θCS | Case-to-sink | °C/W | ≥ 0 °C/W | 4 sig | 0.5 °C/W |
| θSA | Sink-to-ambient | °C/W | ≥ 0 °C/W | 4 sig | 3 °C/W |
| Tjmax | Tj max (blank → 150 °C) | °C | — | 4 sig | 150 °C |
| Tj | Junction temperature | °C | — | 4 sig | — |
| Pmax | Power budget | W | — | 4 sig | — |
| sum | Σθ | °C/W | — | 4 sig | — |
| m | Tjmax − Tj | °C | — | 4 sig | — |
| over | Tj > Tjmax | — | — | 1 sig | — |
| θSA_req | Required θSA | °C/W | — | 4 sig | — |
Worked example
10 W, 25 °C, 1.5 / 0.5 / 3 °C/W
| Input | Value |
|---|---|
| mode · Mode | forward |
| P · Dissipation | 10 W |
| Ta · Ambient | 25 °C |
| θJC · Junction-to-case | 1.5 °C/W |
| θCS · Case-to-sink | 0.5 °C/W |
| θSA · Sink-to-ambient | 3 °C/W |
| Tjmax · Tj max (blank → 150 °C) | 150 °C |
| Output | Value |
|---|---|
| Tj · Junction temperature | 75 °C |
| Pmax · Power budget | 25 W |
| sum · Σθ | 5 °C/W |
| over · Tj > Tjmax | no |
Required θSA for Tjmax 125 °C
| Input | Value |
|---|---|
| mode · Mode | solve_theta_SA |
| P · Dissipation | 10 W |
| Ta · Ambient | 25 °C |
| θJC · Junction-to-case | 1.5 °C/W |
| θCS · Case-to-sink | 0.5 °C/W |
| Tjmax · Tj max (blank → 150 °C) | 125 °C |
| Output | Value |
|---|---|
| θSA_req · Required θSA | 8 °C/W |
How it works
Junction temperature is a stack of three thermal resistances, not a single θJA pulled from a blog. Enter dissipation, ambient, and the three θ values from the datasheet and TIM note. The solve mode hides the entered θSA and reports the heat-sink you still need.
Pitfalls
- Using a website package θ table with no datasheet citation. This page does not invent those numbers.
- Leaving θCS at 0 when the TIM or insulator is not negligible.
- Treating Pmax as a continuous rating when the datasheet derates by airflow and altitude.
FAQ
What is Tj for 10 W at 25 °C with 1.5 + 0.5 + 3 °C/W?
75 °C. Pmax at Tjmax 150 °C is 25 W.
What if I leave Tjmax blank?
The page uses 150 °C, a common silicon default. Enter the datasheet limit when you have it.
How do I size the heat sink?
Switch to “solve required θSA”. The entered θSA is ignored in that mode.
Why is there no TO-220 θ table?
Uncited package numbers are worse than a blank. Copy θJC from the datasheet.